Threaded spheres

OT EQUATOR M1.6

With its 2.1 mm vertical height and 4.4 mm width, the new OT Equator profile offers the lowest profile and the smallest footprint compared to any overdenture on the market for unthreaded Cad/Cam bars (and present in the major software on the market), and for prefabricated burn-out bars made in the laboratory. The OT Equator profile kit with sheath to be bonded includes the abutment with a threaded pitch of 1.6mm and a Titanium sheath of 2.5mm height and external diameter of 2.2mm, to be bonded. For those laboratories that intend to use the calcinable technique, the kit includes one spacer per sheath. There are 4 types of retentive copings with different degrees of retention available, to be used exclusively with the appropriate container facilitating maintenance by the dental office and laboratory.

In addition to the instruments, black copings are available for exclusive use in the laboratory.

PRODCUT INFO

DENTAL CLINIC

LABORATORY

PRODUCT SPECIFICATIONS

VIDEO

PRODCUT INFO

Ref. 160EQB

OT EQUATOR THREADED SLEEVE SYSTEM KIT
FOR BONDING

Kit contains:

2 EQUATOR THREADED (for titanium sleeve 1.6 mm thread)
2 THREADED SLEEVES (1.6 mm thread)
2 STAINLESS STEEL HOUSINGS
2 EQUATOR SPACERS
8 RETENTIVE CAPS (2 extra-soft, 2 soft, 2 standard, 2 processing)


Ref. 192ECE

CAPS ASSORTMENT KIT

Kit contains:

• 1 STAINLESS STEEL HOUSING
 1 PROCESSING CAP
 1 PROTECTIVE DISK
 4 RETENTIVE CAPS (1 extra-soft, 1 soft, 1 standard, 1 strong)


SPARE PARTS


Ref. 339SFE

1 OT EQUATOR (for titanium sleeve - threaded 1.6mm)


Ref. 239GSF

1 TITANIUM SLEEVE (1.6mm threaded)


Ref. 339SSE

1 OT EQUATOR SPACER


Ref. 0140CEV

4 RETENTIVE CAPS / VIOLET (strong 2700g)


Ref. 140CET

4 RETENTIVE CAPS / CLEAR (standard 1800g)


Ref. 140CER

4 RETENTIVE CAPS / YELLOW (extra-soft 600g)


Ref. 140CEN

4 RETENTIVE CAPS  / BLACK (for laboratory use only)


Ref. 141CAE

2 STAINLESS STEEL HOUSINGS


Ref. 141CTE

2 TITANIUM HOUSINGS / FUCHSIA ANODIZED


TOOLS


Ref. 774CHE

1 OT EQUATOR SQUARE SCREW DRIVER + HOLDER (SQUARE 1.25mm) (USABLE WITH RATCHET TORQUE CONTROL DEVICE)


Ref. 760CE

1 SQUARE DRIVER CONNECTOR FOR TORQUE
CONTROLLER CONTRA ANGLE (SQUARE 1.25mm)


Ref. 485IC

1 MULTIUSE CAPS INSERTER/EXTRACTOR TOOL


Ref. 760CRD

1 RATCHET TORQUE CONTROL DEVICE
(FOR OT EQUATOR, SPHERO BLOCKAND FLEX 15/35NCM STRENGHT - MAX 50NCM TORQUE, SUGGESTED 25NCM)


LABORATORY

Step by step threaded sleeve bonding procedure

Once the bar has been connected with wax, create an area where the attachment spacer will be placed.

Apply separator to the base of the attachment spacer and postion using the parallelometer key.

Completare la modellatura con gli spaziatori (OT CAP micro) in posizione.

With the attachment spacer in position, complete the wax-up design.

Screw the threaded attachment of choice (micro sphere shown) into the threaded sleeve.

Place the assembled attachment into the parallelometer key. Use a self curing metal to metal bonding composite on the sleeve and in the cylinder.

After the composite is cured, remove any excess material.


Unscrew the attachment to verify if the threaded sleeve is securely bonded in plac.

The finished bar complete with attachments.

The technique is the same for all 3 method