Threaded Sleeve for Bonding 1.6 F

The low profile OT Equator attachment for bar connections is manufactured with a 1.6 mm thread, 2 sided titanium bonding sleeve, and a base spacer. This new system offers laboratories two cost effective options for placing the attachment on CAD/CAM milled or cast bar overdenture connections. The OT Equator is the smallest attachment in it's classification. Dimensions are 2.1 mm high and 4.4 mm wide with cap in place.
Technicians can select between screwing the threaded OT Equator directly into a milled site, or use the base spacer and bonding sleeve with traditional casting techniques which eliminates the need for drilling and tapping. Once the bar is cast, the OT Equator and sleeve are screwed together and bonded directly into the attachment location.
The OT Equator kit comes complete with 2 titanium nitrate coated attachments, 2 titanium bonding sleeves, 2 base spacers, an assortment of caps and 2 stainless steel housings.

info product
study
laboratory
product specification
Video and Documents

Info Product

OT Equator - Attacchi Filettati da incollare
Ref. 160EQB

Confezione contenente:
• 2 EQUATOR FILETTATO per guaina in titanio (filetto 1.6 mm)
• 2 GUAINE FILETTATE (filetto 1.6 mm)
• 2 CONTENITORI INOX DI CAPPETTE
• 2 SPAZIATORI IN ACCIAIO (per guaina filettata)
• 8 CAPPETTE RITENTIVE (2 extra-soft, 2 soft, 2 standard,
2 processing )


Ricambi


equator-perfilettato 2e2Ref. 0339SFE2      -1 OT Equator Filettato 2 mm - Filetto Standard


equator-perfilettato 1e6Ref. 339SFE      -1 OT Equator Filettato 1.6 mm - Per guaina in Titanio


Guaina Ref 339GDFRef. 239GSF      -1 Guaina in Titanio, Filetto 1.6mm


Spaziatore Ref 339SSE  Ref. 339SSE      -1 Spaziatore per guaina OT Equator


Strumenti


Chiave parallel Ref 744AC01Ref. 74AC01      - Chiave per paralellometro - Normo


Chiave Equator dinamometrica 2014 Holder-InseritoRef. 774CHE      -  Chiave quadrata + Holder per avvitare
OT-EQUATOR (quadrato 1.25mm)


Holder Equator 774HCRef. 774HC        - Holder intercambiabile

Study

Laboratory

Once the bar is connected, create the space where the threaded connection with sheath will be positioned.

Choose the attachment spacer and after having isolated it, position it with the appropriate key.

Complete the modeling with the spacers (Ot Cap micro) in place.

Remove the spacers and proceed to merge the bar.

Screw the attachment (Ot Cap Micro) into the threaded sheath.

Place the assembled attachment with the threaded sheath (Ot Cap Micro) in the key and apply metal-metal anaerobic composite on the sheath and in the hole.

Wait for the composite to harden, then proceed to finishing.

Once the composite has hardened, the attachment can be unscrewed to check the perfect adhesion of the composite material

Finished bar with attacks in position.
The interchangeability of the attachment is guaranteed by the threaded sheath glued into the bar

Product Specifications

Normo
Ø 2.5 mm
Hexagon

1.3mm

Thread 2mm

Micro 
Ø 1.8 mm

Hexagon

0.8mm
Thread 2mm